Craftsman 82140 Bedienungshandbuch Seite 1

Stöbern Sie online oder laden Sie Bedienungshandbuch nach Multimeter Craftsman 82140 herunter. Craftsman 82140 Owner`s manual [en] Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 21
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
1
Owner's Manual
Digital MultiMeter
Model No. 82140
and
Voltage Detector
Model No. 82174
© Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
www.craftsman.com 070606
!
Safety
! Operation
! Maintenance
! Español
CAUTION: Read, understand and
follow Safety Rules and Operating
Instructions in this manual before
using this product.
Seitenansicht 0
1 2 3 4 5 6 ... 20 21

Inhaltsverzeichnis

Seite 1 - Voltage Detector

1 Owner's Manual Digital MultiMeter Model No. 82140 and Voltage Detector Model No. 82174 © Sears, Roebuck and Co., Hoffman

Seite 2 - TABLE OF CONTENTS

10 OPERATING INSTRUCTIONS WARNING: Risk of electrocution. High-voltage circuits, both AC and DC, are very dangerous and should be measured with great

Seite 3 - ONE YEAR FULL WARRANTY

11 AC VOLTAGE MEASUREMENTS WARNING: Risk of Electrocution. The probe tips may not be long enough to contact the live parts inside some 240V outlets f

Seite 4 - SAFETY INSTRUCTIONS

12 DC CURRENT MEASUREMENTS CAUTION: Do not make current measurements on the 10A scale for longer than 30 seconds. Exceeding 30 seconds may cause dama

Seite 5 - SAFETY SYMBOLS

13 RESISTANCE MEASUREMENTS WARNING: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any re

Seite 6 - SYMBOLS AND ANNUNCIATORS

14 DIODE TEST 1. Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive diode jack. 2.

Seite 7 - SPECIFICATIONS

15 MAINTENANCE WARNING: To avoid electric shock, disconnect the test leads from any source of voltage before removing the back cover or the battery o

Seite 8

16 REPLACING THE BATTERIES WARNING: To avoid electric shock, disconnect the test leads from any source of voltage before removing the battery door. 1.

Seite 9 - BATTERY INSTALLATION

17 TROUBLESHOOTING There may be times when your meter does not operate properly. Here are some common problems that you may have and some easy solutio

Seite 10 - OPERATING INSTRUCTIONS

18 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. FIVE YEAR FULL WARRANTY ON C

Seite 11

19 SAFETY SYMBOLS This symbol adjacent to another symbol, terminal or operating device indicates that the operator must refer to an explanation in t

Seite 12

2 TABLE OF CONTENTS Page Warranty 3 Safety Instructions 4 Safety Symbols 5 Control and Jacks 6 Symbols and Annunciators 6 Specifications 7 Bat

Seite 13

20 SPECIFICATIONS Voltage Sensitivity 100 to 240V AC Frequency 50/60Hz Detection distance <0.2” Over voltage Category III 600V Operating

Seite 14

21 OPERATING INSTRUCTIONS AC VOLTAGE DETECTION To check for the presence of AC electrical voltage in an outlet: 1. Touch the probe tip to a cord

Seite 15 - MAINTENANCE

3 ONE YEAR FULL WARRANTY ONE YEAR FULL WARRANTY ON CRAFTSMAN MANUAL RANGING MULTIMETER If this CRAFTSMAN Manual Ranging MultiMeter fails to give compl

Seite 16

4 SAFETY INSTRUCTIONS This meter has been designed for safe use, but must be operated with caution. The rules listed below must be carefully followed

Seite 17 - SERVICE AND PARTS

5 SAFETY SYMBOLS This symbol adjacent to another symbol, terminal or operating device indicates that the operator must refer to an explanation in the

Seite 18 - Owner's Manual

6 CONTROLS AND JACKS 1. LCD Display 2. Function switch 3. COM jack 4. 10A jack 5. Positive jack Note: Tilt stand, fuse and battery compartment

Seite 19

7 SPECIFICATIONS Function Range Resolution Accuracy 200mV 0.1mV 2000mV 1mV 20V 0.01V 200V 0.1V DC Voltage (V DC) 600V 1V %(0.5% reading + 2 d

Seite 20

8 SPECIFICATIONS Diode Test Test current of 1mA maximum, open circuit voltage 2.8V DC typical Continuity Check Audible signal will sound if the resi

Seite 21

9 BATTERY INSTALLATION WARNING: To avoid electric shock, disconnect the test leads from any source of voltage before removing the battery door. 1. Di