Sears, Roebuck and Co. CompuCarve™ System (Rev 1.18) 04/23/07
20
Measuring a Board
The Measure Board function allows the user to measure the width or
length of an existing board. Simply load a board in the typical way and
press the ‘7’ (Measure) key on the keypad or use the up/down arrows to
navigate from the main menu. The display will then ask for the direction
the user wishes to measure.
Configuration Menu Options
The configuration menu allows the user to set project and machine
settings as well as access important run-time and serial number data. To
access the Configurations Menu, select the “0” (Options) key at the
CarveWright Main Menu or use the up/down arrows to locate the menu
and press ENTER. Use the up/down arrows to navigate to the following
menu options:
1) Quality (Default, Draft, Normal, Best)
The Quality menu option lets the user change the carving quality of
the project on the fly. Selecting default will use the settings selected
in the Designer software.
2) Version
The Version menu option will display the version number of the
control system firmware.
3) Usage Odometer
The Usage Odometer menu option will display the usage of the
machine in hours and minutes.
4) Show Serial Number
Selecting the Show Serial Number menu option will display the
machine’s unique serial number.
5) Jog Touch (Off/On)
Setting this option to On configures the machine so that the user is
required to manually set the location of the bit tip for the surface find
operation. During the project setup, the machine will prompt the user
to jog the bit tip over the location on the workpiece that will serve as
the top surface for the project. This is particularly useful when there
are already features carved into the material that prohibit the
machine from automatically detecting the top surface of the material.
The default setting is Off which allows the machine to automatically
find the top surface of the material.
6) Calibrate offsets
The Calibrate Offsets function is a simple procedure to allow the user
to fine-tune the machine for improved accuracy.
7) Sensor Check
The Sensor Check menu options allow access to all of the machine’s
real-time senor readings.
8) Sleep After (off, 1, 5, 10, 15, 30, 45, 60 min)
The Sleep After option is used to set when the electronics go into a
low power sleep mode. This interval is measures from the last
keypad command.