Craftsman CompuCarve 133.217540 Betreibershandbuch Seite 42

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 46
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 41
Sears, Roebuck and Co. CompuCarve™ System (Rev 1.18) 04/23/07
41
Calibrating Machine Offsets: The "Calibrate Offsets" function is a
simple procedure to allow the user to fine-tune the CompuCarve
machine for improved accuracy. To perform the offset calibration the
following will be needed:
- A board at least 2" wide by 10" long between 1/2" and 3/4" thick.
- The CompuCarve branded 3/8" Jointing Bit (using a non-
CompuCarve branded bit will affect accuracy).
- The CompuCarve sensor calibration will vary slightly depending on
the color and darkness of the material. Best results will be realized
by calibrating the machine using that wood type most often used in
the machine. If a variety of woods are used in the machine,
choose a wood for calibration that is in the middle of the range of
color and darkness.
For best results, choose a straight, flat board that has crisp, clean
corners, and ensure that the Jointing bit is in good shape. Begin by
measuring the thickness of the board chosen. Try to measure to within
at least 1/32" of the actual thickness.
Load the board in to the machine and navigate to the Configurations
Menu from the CarveWright Main Menu by using the up/down arrows
or pressing the “0” (Options) key on the keypad. Navigate to or select
item 6, Calibrate Offsets. The machine will prompt for the thickness
that was just measured, key in the value and press ENTER. The
machine will begin measuring the board and then will prompt for the
3/8" Jointing bit. Load the bit as normal and press ENTER. The
machine will take a few more measurements and cut a slot into the
board.
Once the slot is complete, the CarveWright will begin alternating
between measurement and cuts along the two sides of the slot and the
two sides of the board. When the machine has completed the
calibration the new offsets will be stored into the machine and the LCD
will return to the Configurations Menu. The entire process takes just a
few minutes. If the calibration fails, please see the entry entitled
Troubleshooting the Board Sensor in the above paragraph.
Checking the Head Pressure: Cranking the head down onto the
workpiece assures that there is sufficient pressure to move the
workpiece in and out of the machine on the traction belt drive. If there
is not enough head pressure, the sensors that monitor whether the
workpiece is inserted correctly will not operate properly. If this
happens then the message “Please Insert Board” may persist on the
LCD.
Seitenansicht 41
1 2 ... 37 38 39 40 41 42 43 44 45 46

Kommentare zu diesen Handbüchern

Keine Kommentare